Nature of Source Flow: | Active Inverter |
---|---|
Certification: | CCC, ISO9001, RoHS, CE, SGS |
Output Power: | 8000W |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
RCC-03 remote control and programming center
battery status processor BSP
communication module Xcom-232i, equipped with a serial port RS-232
communication sets by internet with Xcom-LAN / Xcom-GSM
communication module Xcom-SMS
multi-protocol communication module Xcom-CAN
and more..
Model |
XTH 3000-12 | XTH 5000-24 | XTH 6000-48 | XTH 8000-48 | |
Characterisation of the operating performance | |||||
Nominal battery voltage | 12V | 24V | 48V | 48V | |
Input voltage range | 9.5-17VDC | 19-34VDC | 38-68VDC | 38-68VDC | |
Continuous Power | 2500VA | 4500VA | 5000VA | 7000VA | |
Power 30 min. | 3000VA | 5000VA | 6000VA | 8000VA | |
Power 5 Sec. | 7.5KVA | 12KVA | 15KVA | 21KVA | |
Max.efficiency | 93% | 94% | 96% | 96% | |
Own consumption stand by | 1.4W |
1.8W |
2.2W |
2.4W |
|
Own consumption stand by | 14W |
18W |
22W |
30W |
|
Acoustic level without ventilation | 40 dB |
||||
Acoustic level with ventilation | 45 dB | ||||
Maximum load | Up to short-circuit | ||||
Maximum asymmetric load | Up to Pcont. | ||||
Load detection (stand-by) | 2 to 25 W |
||||
Cos φ | 0.1-1 | ||||
Output voltage | Pure sine wave 230Vac (±2%) / 120Vac (1) | ||||
Output frequency | 45Hz-60Hz(1) ± 0.05% (crystal controlled) | ||||
Harmonic distortion | <2% | ||||
Overload and short-circuit protection | Automatic disconnection with 3 time restart attempt |
||||
Overheat protection | Warning before shut-off - with automatic restart | ||||
Battery charger | |||||
Charge Characteristic | 6 steps : Bulk-Absorption-Floating-Equalization-reduced floating-periodic absorption Number of steps,thresholds,end current and times completely adjustable with the RCC-02/03 | ||||
Temperature compensation | With BTS-01 or BSP 500/1200 | ||||
Maximum charging current | 160A | 140A | 100A | 120A | |
Input voltage range | 150 to 265Vac / 50 to 140Vac (1) | ||||
Input frequency | 45 to 65Hz | ||||
Input current max . (transfer relay) / Output current max . | 50Aac / 56Aac | ||||
Transfer time | < 15ms | ||||
Protection index | IP 20 | ||||
Operating temperature range | -20 to 55ºC | ||||
Ventilation | Forced from 55ºC | ||||
Warranty | 5 Years |
Suppliers with verified business licenses